The recommended operating voltage range for the DS26C31MJ/883 is 4.5V to 5.5V.
To ensure reliable data transmission, ensure that the transmitter and receiver are properly terminated, and the transmission line is properly matched to the characteristic impedance of the device (typically 100 ohms).
The DS26C31MJ/883 supports data rates up to 1 Mbps.
To handle common-mode noise, use a common-mode choke or a ferrite bead in the transmission line, and ensure that the transmitter and receiver are properly grounded.
Yes, the DS26C31MJ/883 can be used in a multi-point application, but ensure that the total bus length does not exceed 4000 feet (1219 meters) and that the total number of nodes does not exceed 32.