    DS600U datasheet by Maxim Integrated Products

    • ±0.5 accurate analog-output temperature sensor
    • Original
    • No
    • No
    • Obsolete
    • EAR99
    • 8542.39.00.01
    • 8542.39.00.00
    • Find it at Findchips.com

    DS600U datasheet preview

    DS600U Frequently Asked Questions (FAQs)

    • The DS600U requires a careful layout and routing to minimize noise and ensure accurate measurements. It is recommended to keep the analog and digital grounds separate, use a solid ground plane, and keep the signal traces short and away from noise sources. Additionally, use a low-pass filter on the input signals to reduce high-frequency noise.
    • The DS600U requires calibration to ensure accurate measurements. Calibration involves adjusting the internal offset and gain of the device to match the specific application requirements. This can be done using the CAL pin and an external calibration voltage source. Refer to the application note AN1651 for detailed calibration procedures.
    • The maximum input voltage range for the DS600U is ±10V. To protect the device from overvoltage, it is recommended to use external voltage limiting resistors or clamping diodes to limit the input voltage to within the specified range.
    • The DS600U can be interfaced with a microcontroller or FPGA using a serial communication protocol such as SPI or I2C. The recommended communication protocol is SPI, which allows for fast and efficient data transfer. The device requires a 3-wire interface (SCLK, SDI, and SDO) for SPI communication.
    • The power consumption of the DS600U is typically around 10mA. To minimize power consumption, it is recommended to use a low-power mode when the device is not in use, and to optimize the power supply voltage to the minimum required for the application.