The maximum cable length supported by the DS90LV027ATM is 10 meters, but it can be extended up to 15 meters with proper termination and cable selection.
To ensure signal integrity, use a differential pair for clock and data signals, keep the trace length and impedance matched, and use a common mode choke or ferrite bead to reduce EMI.
The recommended power-up sequence is to power up the VCC supply first, followed by the VCCA supply, and then the input clock signal.
To handle skew and jitter, use a clock signal with a low jitter and skew, and use the built-in deskew feature of the DS90LV027ATM to compensate for any remaining skew.
The maximum data rate supported by the DS90LV027ATM is 1.5 Gbps, but it can be extended up to 3 Gbps with proper system design and signal conditioning.