The recommended operating temperature range for the DS91C176TMAX/NOPB is -40°C to 85°C.
To ensure reliable data transmission over the LVDS interface, make sure to follow the recommended PCB layout guidelines, use a differential impedance of 100 ohms, and maintain a common-mode voltage of 1.2V.
The maximum clock frequency supported by the DS91C176TMAX/NOPB is 66 MHz.
To configure the device for point-to-point or multi-drop applications, use the MODE pins to select the desired configuration. For point-to-point, tie MODE0 and MODE1 high. For multi-drop, tie MODE0 low and MODE1 high.
The power consumption of the DS91C176TMAX/NOPB is typically 150 mW at 3.3V and 66 MHz.