The recommended termination impedance is 15 ohms to ensure optimal signal integrity and minimize reflections.
Apply a DC voltage of 3.3V ±10% to the VDD pin, and ensure the VSS pin is connected to a reliable ground plane to minimize noise and ensure stable operation.
The maximum allowable frequency deviation is ±50 ppm over the entire operating temperature range of -40°C to +85°C.
While the F4100-333 is designed for 3.3V operation, it can operate with a supply voltage range of 2.7V to 3.6V, but this may affect its performance and frequency stability.
Use a high-quality, low-ESR decoupling capacitor (e.g., 0.1 μF) close to the VDD pin, and ensure a low-inductance path to the ground plane to minimize noise and jitter.