A 4-layer PCB with a solid ground plane and a separate power plane is recommended. Keep the input and output traces short and away from each other to minimize crosstalk.
The GC4016-PBZ requires a bias voltage of 5V ± 10%. Ensure the power supply is stable and decoupled with 0.1uF and 10uF capacitors to minimize noise and ripple.
The GC4016-PBZ is rated for operation from -40°C to 85°C. However, it's recommended to derate the device by 1°C/W above 25°C to ensure reliable operation.
Use ESD protection devices such as TVS diodes or ESD arrays on the input and output pins. Ensure the PCB layout provides a clear path for ESD discharge to ground.
Use a 50Ω termination resistor in series with a 0.1uF capacitor to ground on the output pins. This helps to reduce reflections and improve signal integrity.