The recommended operating voltage range for the HEF4011BD is 5V to 15V, with a typical voltage of 10V.
To ensure proper operation, the inputs should be driven from a source with a low impedance and should not be left floating. If an input is not used, it should be tied to VDD or GND through a resistor to prevent unwanted switching.
The maximum frequency of operation for the HEF4011BD is typically around 10 MHz, but this can vary depending on the specific application and operating conditions.
The HEF4011BD can sink or source up to 1 mA of current per output, but this should be limited to ensure that the total output current does not exceed 10 mA to prevent overheating.
Yes, to minimize noise and ensure proper operation, it is recommended to keep the input and output traces short and away from each other, and to use a ground plane to reduce electromagnetic interference (EMI).