The recommended operating voltage range for the HEF4013BP is 3V to 15V, with a typical voltage of 5V.
To ensure proper power-on and power-off, it is recommended to use a power-on reset circuit and a decoupling capacitor (e.g., 100nF) between VCC and GND.
The maximum clock frequency that the HEF4013BP can handle is 10MHz, but this can vary depending on the specific application and operating conditions.
To prevent latch-up, ensure that the input signals are properly terminated and that the device is not exposed to excessive voltage or current. Also, use a latch-up protection circuit if necessary.
The maximum power dissipation of the HEF4013BP is 500mW, but this can vary depending on the specific application and operating conditions.