The recommended torque for the terminals is 0.5-0.8 Nm (4.4-7.0 in-lbs). It's essential to follow this torque specification to ensure reliable connections and prevent damage to the device.
Yes, the HL251-73 is designed to withstand high-vibration environments. It meets the IEC 60068-2-6 vibration test standard, which ensures reliable performance in applications with intense vibrations.
The HL251-73 has a rating of IP67, which means it is protected against dust and can withstand immersion in water up to 1 meter for 30 minutes. However, it's essential to ensure proper sealing and installation to maintain this rating.
The HL251-73 has an operating temperature range of -40°C to 125°C (-40°F to 257°F). It's essential to ensure the device operates within this range to maintain its performance and reliability.
Yes, the HL251-73 is designed to handle high inrush currents. It has a high surge withstand capability, making it suitable for applications with high inrush currents, such as motor control and power supply circuits.