The recommended operating temperature range for the HLMP-3590 is -40°C to 85°C, although it can withstand storage temperatures from -40°C to 150°C.
To ensure proper soldering, follow the recommended soldering profile and use a solder with a melting point above 217°C. Also, make sure the PCB is designed with a suitable thermal pad and land pattern to accommodate the HLMP-3590's package.
The maximum current rating for the HLMP-3590 is 30mA per channel, with a total current rating of 60mA for both channels.
To prevent ESD damage, handle the HLMP-3590 with ESD-safe materials, wear an ESD strap, and ensure the workspace is ESD-protected. Also, follow proper handling and storage procedures to minimize the risk of ESD damage.
The HLMP-3590 is designed to operate in a relative humidity range of 5% to 95%. However, it's recommended to follow proper moisture-sensitive device handling and storage procedures to prevent damage.