    Part Img INA210AIDCKRG4 datasheet by Texas Instruments

    • INA210 - Voltage Output, High/Low-Side Measurement, Bi-Directional Zero-Drift Series Current Shunt Monitor 6-SC70 -40 to 125
    • Original
    • Yes
    • Obsolete
    • EAR99
    • 8542.33.00.01
    • 8542.33.00.00
    • Powered by Findchips Logo Findchips

    INA210AIDCKRG4 datasheet preview

    INA210AIDCKRG4 Frequently Asked Questions (FAQs)

    • The maximum voltage that can be applied to the input pins is ±40V, but it's recommended to keep it within the common-mode voltage range of ±26V to ensure accurate measurements.
    • The gain error can be calculated using the formula: Gain Error (%) = (Vout / (Gain x Vin)) x 100, where Vout is the output voltage, Gain is the gain setting, and Vin is the input voltage.
    • The CAP pin is used to connect a capacitor to filter out high-frequency noise and improve the accuracy of the measurements. A 10nF to 100nF capacitor is recommended, and it should be connected between the CAP pin and the GND pin.
    • To configure the INA210 for bidirectional current measurement, connect the input pins (VIN+ and VIN-) to the sense resistor, and set the gain to a suitable value. The output voltage will be proportional to the current flowing through the sense resistor, and the direction of the current can be determined by the polarity of the output voltage.
    • The INA210 can handle input frequencies up to 350 kHz, but the bandwidth may be limited by the gain setting and the external components used.