The maximum operating frequency of the IR2304SPBF is 1 MHz, but it can be operated up to 2 MHz with reduced performance.
To ensure the bootstrap capacitor is properly charged, make sure the high-side driver is enabled before the low-side driver, and the bootstrap capacitor is sized correctly based on the switching frequency and output current.
The recommended dead time between the high-side and low-side drivers is typically around 100-200 ns to prevent shoot-through and ensure proper operation.
The IR2304SPBF is designed to operate with a 15V supply voltage, but it can be used with a different voltage supply within the recommended operating range of 10V to 20V, with proper consideration of the output current and power dissipation.
To protect the IR2304SPBF from overcurrent and overheating, use a current sense resistor and a thermal monitoring circuit to detect and respond to overcurrent and overheating conditions.