The maximum operating temperature range for the LCM300U-T is -40°C to 85°C, with a derating of 2.5% per °C above 70°C.
Yes, the LCM300U-T can be used in a redundant configuration to provide high availability and fault tolerance. Artesyn provides guidelines for implementing redundancy in the product manual.
The MTBF of the LCM300U-T is approximately 1.4 million hours, calculated according to the Telcordia SR-332 Issue 3 standard.
Yes, the LCM300U-T supports hot-swapping, allowing users to replace the power supply unit (PSU) without shutting down the system.
The LCM300U-T can tolerate input voltage surges of up to 300V for 100ms, making it suitable for use in environments with unstable power grids.