A 4-layer PCB with a solid ground plane and a separate power plane is recommended. Keep the high-frequency traces short and away from the power plane. Use a common mode choke or a ferrite bead to filter the power supply.
Use a high-quality, low-ESR capacitor in the LC tank circuit. Ensure the inductor is properly connected and the PCB layout is optimized for minimal parasitic inductance. Calibrate the device using a known inductor value.
The maximum operating frequency is 1 MHz, but it can be extended to 2 MHz with proper PCB layout and component selection. However, this may affect the accuracy of the inductance measurements.
No, the LDC0851HDSGT is designed specifically for inductance measurements. It is not suitable for capacitance measurements. Use a different device, such as the LDC1612, for capacitance measurements.
Use a shielded enclosure, keep the device away from noise sources, and use a low-pass filter or a ferrite bead to filter the power supply. Implement a noise-reducing algorithm in the firmware, such as averaging or median filtering.