The maximum operating temperature range for the LM5067MM-2/NOPB is -40°C to 125°C.
To ensure stability, use a minimum output capacitance of 10uF, and ensure that the output capacitor has a low ESR (Equivalent Series Resistance) of less than 1 ohm.
The recommended input capacitor value is 10uF to 22uF, with a voltage rating of at least 2x the input voltage.
Yes, the LM5067MM-2/NOPB can handle high currents, but ensure that the PCB layout is designed to handle the high current, and that the thermal dissipation is adequate to prevent overheating.
Power dissipation can be calculated using the formula: Pd = (Vin - Vout) x Iout, where Vin is the input voltage, Vout is the output voltage, and Iout is the output current.