The LM75ADP,118 can operate from -40°C to 125°C, but the accuracy of the temperature measurement is guaranteed from -20°C to 100°C.
-
The LM75ADP,118 has an accuracy of ±2°C from -20°C to 100°C, and ±3°C from -40°C to -20°C and from 100°C to 125°C.
-
The conversion time for a temperature measurement is approximately 100 ms.
-
Yes, the LM75ADP,118 can be used in a multi-drop bus configuration, allowing multiple devices to share the same bus.
-
The quiescent current of the LM75ADP,118 is typically 10 μA.