The recommended operating voltage range for the LMV602MAX/NOPB is 2.7V to 5.5V.
To ensure stability, it is recommended to use a minimum gain of 5, and to avoid capacitive loads. Additionally, a 10nF to 100nF capacitor can be added between the output and the inverting input to improve stability.
The maximum power dissipation for the LMV602MAX/NOPB is 670mW. It is recommended to ensure that the device does not exceed this power dissipation to prevent overheating.
The LMV602MAX/NOPB is rated for operation up to 125°C. However, it is recommended to derate the power dissipation at higher temperatures to prevent overheating.
To minimize noise and interference, it is recommended to keep the input and output traces short and away from noise sources, use a ground plane, and decouple the power supply with a 10uF capacitor.