The recommended operating voltage range for the M27C1001-15F1 is 4.75V to 5.25V.
The power-up sequence should be VCC first, then OE# and CE#. During power-down, the sequence should be CE# and OE# before VCC. This ensures that the device is properly initialized and avoids any potential latch-up conditions.
The maximum clock frequency supported by the M27C1001-15F1 is 15 MHz.
To ensure data retention, the VCC supply voltage should be reduced to 0V before the CE# and OE# inputs are driven high. This ensures that the device enters a low-power standby mode, and the data is retained.
The maximum storage temperature range for the M27C1001-15F1 is -65°C to +150°C.