MACOM recommends a 4-layer PCB with a solid ground plane, and thermal vias under the device to dissipate heat. A thermal pad on the bottom of the package should be connected to a thermal plane or a heat sink.
MACOM provides a recommended PCB layout and impedance matching circuit in the application note AN-2171. It's essential to follow these guidelines to achieve optimal performance and minimize signal reflections.
The maximum operating temperature for the MAPD-011002 is 85°C. As the temperature increases, the device's performance may degrade, resulting in reduced gain, increased noise figure, and decreased output power.
Yes, the MAPD-011002 can be used in a push-pull configuration to achieve higher output power and improved linearity. This configuration can also help reduce even-order harmonics and improve overall system performance.
MACOM recommends a voltage-controlled biasing scheme, where the gate voltage is set to around -0.5V to -1.5V, and the drain voltage is set to around 20V to 28V. The biasing scheme affects the device's gain, noise figure, and output power, so it's essential to follow the recommended guidelines.