A good PCB layout is crucial for the MAX3600CTL+T. Ensure a solid ground plane, keep the input and output traces short and separate, and use a common mode choke to filter the input power. Refer to Maxim's application note 3881 for a detailed layout guide.
Choose an input capacitor with a low ESR (Equivalent Series Resistance) and a high ripple current rating. A 10uF to 22uF ceramic capacitor with an X7R or X5R dielectric is recommended. Ensure the capacitor is rated for the input voltage and can handle the maximum RMS current.
The MAX3600CTL+T can deliver up to 1.5A of output current. However, the actual output current capability depends on the input voltage, output voltage, and ambient temperature. Refer to the datasheet's thermal derating curves to determine the maximum output current for your specific application.
The MAX3600CTL+T has a built-in overcurrent protection feature. You can set the overcurrent threshold by connecting a resistor between the OCP pin and GND. The device will limit the output current to the set threshold during an overcurrent event.
The EN (Enable) pin is used to turn the device on or off. Connect the EN pin to a logic signal (e.g., a microcontroller output) to enable or disable the device. When EN is low, the device is in shutdown mode, and the output is disconnected from the input.