The MAX485CPA can support data rates up to 2.5 Mbps.
Yes, the MAX485CPA can be used in a multi-point application, but it requires an external circuit to ensure that only one transmitter is active at a time.
To ensure proper termination, a 120-ohm resistor should be connected between the R and T pins, and a 560-ohm resistor should be connected between the R pin and ground.
The maximum cable length that can be used with the MAX485CPA depends on the data rate and the type of cable used. As a general rule, the maximum cable length is 4000 feet at 9600 bps and 1000 feet at 115.2 kbps.
Yes, the MAX485CPA has built-in noise immunity and can operate in noisy environments. It also has a common-mode range of ±7V, which helps to reject noise.