The maximum operating frequency of the MC9RS08LA8CLF is 20 MHz, but it can be overclocked to 24 MHz with some limitations.
The internal clock source can be configured using the CLKSEL register. The clock source can be selected from the internal oscillator, external clock, or the internal RC oscillator.
The maximum current consumption of the MC9RS08LA8CLF is approximately 10 mA at 20 MHz with all peripherals enabled, but this can vary depending on the application and operating conditions.
The ADC module can be used by configuring the ADCSC1 and ADCSC2 registers to select the channel, conversion mode, and clock source. The ADC result can be read from the ADCRH and ADCRL registers.
Yes, the MC9RS08LA8CLF has several low-power modes, including Stop, Wait, and Low-Power Run modes, which can be used to reduce power consumption. The device can also be put into a deep sleep mode using the BDM mode.