The maximum operating frequency of the MC9S08AW60CFDE is 20 MHz, but it can be overclocked to 24 MHz with some limitations.
The internal clock source can be configured using the SYNR and REFS registers. The SYNR register sets the clock source, and the REFS register sets the clock frequency.
The COP module is a watchdog timer that resets the microcontroller if it fails to respond within a specified time period, ensuring that the system remains operational and preventing lockups or hangs.
The ADC module can be used by configuring the ADCSC1 and ADCSC2 registers to select the channel, resolution, and conversion mode. The ADC result can be read from the ADCRH and ADCRL registers.
The maximum current that can be sourced or sunk by the GPIO pins is 25 mA, but it's recommended to limit the current to 10 mA to ensure reliable operation.