STMicroelectronics recommends a PCB layout with a large copper area connected to the tab of the device to ensure good thermal dissipation. A minimum of 2 oz copper thickness is recommended.
The MJD122-1 requires a bias voltage of 5V to 15V, and a bias current of 1mA to 10mA. Ensure the bias circuit is designed to provide a stable voltage and current to the device.
The maximum allowed power dissipation for the MJD122-1 is 2W. Ensure the device is operated within this limit to prevent overheating and damage.
Handle the device with ESD-protective equipment, such as wrist straps and mats. Ensure the PCB design includes ESD protection components, such as TVS diodes or ESD protection arrays.
The recommended storage temperature range for the MJD122-1 is -40°C to 125°C. Ensure the device is stored within this range to prevent damage.