The recommended operating temperature range for NSL-5162 is -40°C to 85°C, although it can operate up to 100°C with reduced performance and lifespan.
Proper thermal management can be achieved by using a heat sink with a thermal conductivity of at least 1 W/m-K, and ensuring good thermal contact between the device and the heat sink. Additionally, keeping the ambient temperature below 50°C can help reduce thermal stress.
The maximum optical power that the NSL-5162 can handle is 23 dBm (200 mW) for a 1-minute duration, and 20 dBm (100 mW) for continuous operation.
Calibration involves adjusting the bias current and voltage to achieve the optimal operating point. This can be done using the recommended calibration procedure outlined in the application note, which involves measuring the device's responsivity and dark current.
The typical response time of the NSL-5162 is around 10 ns, although this can vary depending on the specific application and operating conditions.