The recommended operating voltage range for NX3L2G66GD,125 is 1.65 V to 5.5 V, with a typical voltage of 3.3 V.
To ensure proper thermal management, it's recommended to provide a heat sink or a thermal pad on the exposed pad of the device, and to keep the junction temperature (Tj) below 125°C.
The maximum current rating for the NX3L2G66GD,125 is 50 mA per channel, with a total current limit of 150 mA for all channels combined.
To handle ESD protection, it's recommended to use a human-body model (HBM) of 2 kV and a machine model (MM) of 200 V, and to follow proper handling and storage procedures to prevent ESD damage.
It's recommended to follow a low-inductance PCB layout and routing, with short traces and minimal vias, to minimize signal distortion and ensure proper signal integrity.