    • Sensors, Transducers - Optical Sensors - Ambient Light, IR, UV Sensors - AMBIENT LIGHT SENSOR
    • Original
    • Yes
    • Yes
    • Active
    • EAR99
    • 8542.39.00.01
    • 8542.39.00.00
    • Always verify details of parts you are evaluating, as these parts are offered as suggestions for what you are looking for and are not guaranteed.

    OPT3007YMFR datasheet preview

    OPT3007YMFR Price & Stock

    Distributor Stock Lead Time Min Order Qty Price Buy
    DigiKey () 4,934 1
    • 1 $1.06
    • 10 $0.88
    • 100 $0.76
    • 1000 $0.66
    • 10000 $0.66
    Buy Now
    4,934 1
    • 1 $1.06
    • 10 $0.88
    • 100 $0.76
    • 1000 $0.66
    • 10000 $0.66
    Buy Now
    3,000 3,000
    • 1 -
    • 10 -
    • 100 -
    • 1000 -
    • 10000 $0.59
    Buy Now
    Mouser Electronics 3,780
    • 1 $0.92
    • 10 $0.76
    • 100 $0.73
    • 1000 $0.62
    • 10000 $0.49
    Buy Now
    Quest Components 24,000
    • 1 $2.81
    • 10 $2.81
    • 100 $2.81
    • 1000 $1.05
    • 10000 $1.05
    Buy Now
    Vyrian 8,116
    • 1 -
    • 10 -
    • 100 -
    • 1000 -
    • 10000 -
    Get Quote

    OPT3007YMFR Frequently Asked Questions (FAQs)

    • A good PCB layout practice is to keep the OPT3007YMFR away from other components that may interfere with its light sensing capabilities. A recommended layout is to place the OPT3007YMFR near the edge of the PCB, with a clear path for light to enter the sensor. Additionally, avoid placing the sensor near heat sources or high-current paths.
    • The OPT3007YMFR does not require calibration. It is a digital ambient light sensor that provides a calibrated digital output in lux. However, it's recommended to perform a one-time initialization of the sensor by writing the default values to the configuration registers.
    • The recommended power-on sequence for the OPT3007YMFR is to apply VCC first, followed by EN (enable) and then SCL (clock). This ensures that the sensor is properly initialized and ready for operation.
    • The interrupt output (INT) of the OPT3007YMFR is an active-low, open-drain output that can be connected to a microcontroller's interrupt input. When the sensor detects a change in the ambient light level, it asserts the INT pin low. The microcontroller can then read the sensor data and clear the interrupt.
    • The maximum cable length for the I2C interface of the OPT3007YMFR depends on the system design and the capacitance of the cable. As a general guideline, the cable length should be limited to 10 inches (25 cm) to ensure reliable operation. If a longer cable is required, it's recommended to use a repeater or a buffer to maintain signal integrity.