The recommended operating temperature range for PBYR2025CT is -40°C to 125°C, although the datasheet only mentions a storage temperature range.
To ensure reliability, it's essential to follow proper thermal management practices, such as providing adequate heat sinking, using a thermally conductive interface material, and keeping the junction temperature below 150°C.
Although the datasheet specifies a maximum voltage of 25V, it's recommended to derate the voltage to 20V or lower to ensure long-term reliability and prevent degradation.
Yes, the PBYR2025CT can be used in switching regulator applications, but it's essential to ensure that the device is properly bypassed and that the switching frequency is within the recommended range to prevent oscillations.
To handle high power dissipation, use a heat sink with a thermal resistance of 10°C/W or lower, and ensure good airflow around the device. You can also consider using a thermal interface material to improve heat transfer.