The PCF8584T/2,518 can handle clock frequencies up to 2.5 MHz.
To ensure proper reset, apply a power-on reset pulse to the RST pin, and hold it low for at least 1 ms. This will reset the device and ensure that it starts in a known state.
The X1 and X2 pins are used as external clock input pins. They can be connected to a crystal oscillator or an external clock source to provide a clock signal to the device.
To generate a 1 Hz clock signal, set the clock divider to 4096 and use the internal oscillator. This will divide the internal oscillator frequency by 4096, resulting in a 1 Hz clock signal.
The maximum capacitance that can be connected to the X1 and X2 pins is 20 pF. Exceeding this value may affect the oscillator's stability and frequency.