The maximum input voltage is 60V, but it's recommended to derate the input voltage to 55V for reliable operation.
Use a heat sink with a thermal resistance of 10°C/W or lower, and ensure good airflow around the device. Monitor the junction temperature (TJ) and adjust the heat sink or airflow as needed.
A minimum of 10uF of input capacitance is recommended to ensure stable operation and reduce input voltage ripple.
While the PTH05060WAD is a high-reliability device, it's not specifically designed for aerospace applications. For aerospace applications, consider using a device with a higher temperature rating and more stringent testing and screening.
Use a output capacitor with a low ESR (Equivalent Series Resistance) and a value of at least 10uF. You can also add a small ceramic capacitor in parallel to reduce high-frequency noise.