The recommended operating voltage range for the S-93C46BD0I-I8T1U is 1.7V to 5.5V.
The POR circuitry in the S-93C46BD0I-I8T1U is designed to reset the device during power-up. Ensure that the power supply voltage rises monotonically to avoid false resets. A minimum power-up ramp time of 1ms is recommended.
The S-93C46BD0I-I8T1U supports a maximum clock frequency of 1MHz.
To ensure data retention, the VCC pin should be powered down slowly (less than 1ms) to avoid data corruption. Additionally, the device should be in a standby mode (CE = HIGH) before power-down.
The typical write endurance of the S-93C46BD0I-I8T1U is 100,000 cycles.