The maximum operating temperature range for the S29AS016J70BFI032 is -40°C to +85°C.
The hold signal (HOLD#) should be asserted low to pause the current operation and de-asserted high to resume the operation. During hold, the device will tri-state its outputs and ignore any input signals.
The write protect (WP#) signal is used to prevent accidental writes to the device. When WP# is asserted low, the device will ignore any write commands and protect the contents of the memory.
The device density and organization can be determined by reading the device ID and revision ID registers. The S29AS016J70BFI032 has a density of 16Mb and is organized as 2,097,152 words x 8 bits.
The recommended power-up sequence is to apply VCC first, followed by VPP (if used), and then the clock signal. The device should be in a standby or reset state during power-up.