The maximum operating frequency of the S29GL01GS11DHV010 is 133 MHz.
The hold signal (HOLD#) should be asserted low to pause the flash operation, and de-asserted high to resume the operation.
The write protect (WP#) signal is used to prevent accidental writes to the flash memory. When WP# is low, the flash memory is write-protected.
To perform a sector erase operation, send the erase command (0x20) followed by the sector address to be erased. The erase operation will take approximately 2 seconds to complete.
The recommended power-up sequence is to apply VCC first, followed by VPP, and then the clock signal (CLK).