The maximum operating temperature range for the S29GL128P90FFIR20 is -40°C to +85°C.
The hold signal (HOLD#) should be asserted low to pause the current operation and enter a low-power state. De-asserting HOLD# resumes the operation.
The write protect (WP#) signal is used to prevent accidental writes to the device. When WP# is low, the device is write-protected.
To perform a sector erase operation, send the erase command (0x60h) followed by the sector address. The device will then erase the specified sector.
The reset (RESET#) signal is used to reset the device to its power-on state. Asserting RESET# low for at least tRP (reset pulse width) resets the device.