The recommended operating voltage range for the S34ML01G100BHI000 is 2.7V to 3.6V.
The HOLD and HOLDA signals are used for asynchronous data transfer. To handle them, ensure that your design can generate a HOLD signal to the flash memory when it needs to access the bus, and that the flash memory can respond with a HOLDA signal to acknowledge the request.
The WP pin is used to prevent accidental writes to the flash memory. To use it, connect the WP pin to VCC to enable write protection, or connect it to GND to disable write protection.
To perform a sector erase operation, send the sector erase command (0x20) followed by the address of the sector to be erased. The device will then erase the entire sector.
The S34ML01G100BHI000 supports up to 100,000 erase cycles per sector.