The recommended operating temperature range for the S5106 is -20°C to 70°C. However, it can operate up to 85°C with reduced performance.
Handle the S5106 by the ceramic package only, avoiding touching the optical surface or the wire bonds. Use an anti-static wrist strap or mat to prevent electrostatic discharge damage.
The recommended reverse bias voltage for the S5106 is up to 20V. However, the optimal bias voltage depends on the specific application and may need to be determined experimentally.
Use a soldering iron with a temperature of 250°C or less, and avoid applying excessive force or pressure to the device. Use a solder with a melting point of 180°C or higher, and ensure the soldering time is less than 3 seconds.
The typical response time of the S5106 is around 10 ns, but this can vary depending on the specific application and operating conditions.