The recommended PCB footprint for SBR20A200CT is a standard SOD-123 package with a pad size of 1.5mm x 1.5mm and a thermal pad size of 2.5mm x 2.5mm.
To ensure reliability in high-temperature applications, ensure that the device is operated within its recommended operating temperature range (-55°C to 150°C), and consider using a heat sink or thermal management system to prevent overheating.
The maximum allowable voltage stress for SBR20A200CT is 200V, as specified in the datasheet. Exceeding this voltage may cause damage to the device.
Yes, SBR20A200CT can be used in switching regulator applications due to its fast switching speed and low voltage drop. However, ensure that the device is operated within its recommended operating conditions and that the circuit is properly designed to minimize voltage spikes and ringing.
To prevent ESD damage, handle SBR20A200CT with ESD-protective equipment, such as wrist straps, mats, and bags. Ensure that the device is stored in an ESD-protective package when not in use.