The maximum junction temperature that the STGY50NC60WD can withstand is 150°C.
To ensure reliability, it is recommended to derate the power dissipation of the device according to the ambient temperature, and to use a suitable heat sink to keep the junction temperature below 125°C.
The recommended gate resistor value for the STGY50NC60WD is between 10 ohms and 100 ohms, depending on the specific application and switching frequency.
Yes, the STGY50NC60WD can be used in parallel to increase the current handling capability, but it is recommended to use a current sharing technique, such as a current sense resistor, to ensure equal current distribution between the devices.
The recommended dead time for the STGY50NC60WD in a half-bridge configuration is typically between 100 ns and 500 ns, depending on the specific application and switching frequency.