The maximum operating junction temperature of the T70HFL10S10 is 150°C, but it's recommended to keep it below 125°C for reliable operation.
Proper cooling can be achieved by using a heat sink with a thermal resistance of less than 1°C/W, and ensuring good airflow around the device. The heat sink should be mounted using a thermal interface material with a thermal conductivity of at least 1 W/m-K.
The recommended gate drive voltage for the T70HFL10S10 is between 10V and 15V, with a maximum gate-source voltage of 20V.
Yes, the T70HFL10S10 can be used in a parallel configuration, but it's essential to ensure that the devices are matched for gate threshold voltage and that the gate drive circuitry is designed to handle the increased gate capacitance.
The maximum allowable dv/dt for the T70HFL10S10 is 1000 V/μs, but it's recommended to limit it to 500 V/μs or less to ensure reliable operation.