The maximum clock frequency for TLC0831CP is 3.5 MHz. However, it's recommended to use a clock frequency of 2.5 MHz or less to ensure reliable operation.
The TLC0831CP has a built-in POR circuit that resets the device when the power supply voltage (VCC) rises above 1.5V. To handle POR, ensure that the VCC ramp-up time is slower than 10 ms/V to prevent false triggering.
The recommended operating voltage range for TLC0831CP is 4.5V to 5.5V. Operating the device outside this range may affect its performance and accuracy.
TLC0831CP can be interfaced with a microcontroller using a 3-wire serial interface (CLK, DIN, and DOUT). The microcontroller can send commands and data to the TLC0831CP using the DIN pin, and receive data from the TLC0831CP using the DOUT pin.
The /CS pin is used to select or deselect the TLC0831CP device. When /CS is low, the device is selected and data can be transferred. When /CS is high, the device is deselected and data transfer is inhibited.