Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    Part Img TLC0832ID datasheet by Texas Instruments

    • 8 Bit Analog-to-Digital Converter with Serial Control
    • Original
    • Yes
    • Yes
    • Active
    • EAR99
    • 8542.39.00.01
    • 8542.39.00.00
    • Powered by Findchips Logo Findchips

    TLC0832ID datasheet preview

    TLC0832ID Frequently Asked Questions (FAQs)

    • The maximum clock frequency for TLC0832ID is 3.6 MHz. However, it's recommended to use a clock frequency of 2.5 MHz or less to ensure reliable operation.
    • The TLC0832ID has a built-in POR circuit that resets the device when the power supply voltage (VCC) rises above 1.5 V. To handle POR, ensure that the VCC ramp-up time is slower than 10 ms/V to prevent false triggering of the POR circuit.
    • The recommended operating voltage range for TLC0832ID is 4.5 V to 5.5 V. Operating the device outside this range may affect its performance and reliability.
    • TLC0832ID can be interfaced with a microcontroller using a 3-wire serial interface (CLK, DIN, and DOUT). The microcontroller should provide a clock signal to the CLK pin, and data is transmitted serially through the DIN pin. The TLC0832ID then converts the serial data to analog voltage outputs.
    • The settling time of TLC0832ID is typically 20 μs. This is the time it takes for the output voltage to settle within ±1 LSB of the final value after a code change.