The recommended operating voltage range for TLC3704IDR is 2.7V to 5.5V.
To ensure proper power-up and initialization, connect the VCC pin to a stable voltage source, and ensure the input voltage ramps up slowly (typically 10ms to 100ms) to prevent latch-up.
The maximum frequency of operation for TLC3704IDR is 100 kHz, but it can be operated at higher frequencies with reduced amplitude and increased power consumption.
To prevent damage, ensure the output stage is properly terminated with a load impedance, and avoid short-circuiting the output pins to prevent excessive current flow.
The thermal derating for TLC3704IDR is 1.5°C/W above 25°C, and the maximum junction temperature is 150°C.