The maximum clock frequency of the TM4C123GH6PZI7 is 80 MHz.
The pin muxing on the TM4C123GH6PZI7 can be configured using the Pin Muxing Register (PMCn) and the Pin Configuration Register (PCn).
The TM4C123GH6PZI7 has 256 KB of flash memory.
The ADC on the TM4C123GH6PZI7 can be used by configuring the ADC control registers (ADCnCTL) and enabling the ADC clock. The ADC conversion result can be read from the ADC result register (ADCnRIS).
The NMI (Non-Maskable Interrupt) pin on the TM4C123GH6PZI7 is used to trigger a non-maskable interrupt, which can be used to respond to critical events such as a watchdog timer timeout or a power failure.