The TMP102AIDRLRG4 can operate from -40°C to 125°C, but the accuracy is specified from -20°C to 100°C.
The TMP102AIDRLRG4 defaults to 12-bit resolution. To configure it for 13-bit resolution, set the EM bit (bit 7 of the configuration register) to 1.
The conversion time for the TMP102AIDRLRG4 is approximately 30 ms.
Yes, the TMP102AIDRLRG4 supports multi-drop configuration, allowing multiple devices to share the same bus.
The TMP102AIDRLRG4 has an alert function that can be configured to trigger an interrupt when the temperature exceeds a set threshold. The alert function is enabled by setting the AL bit (bit 5 of the configuration register) to 1.