The recommended operating voltage range for the TMS3705BDRG4 is 3.3V to 5V.
To ensure reliable communication, make sure to use pull-up resistors on the SCL and SDA lines, and ensure that the clock frequency does not exceed 400 kHz.
The TMS3705BDRG4 can sink or source up to 4mA on its I/O pins.
The POR and BOR features are enabled by default. To disable them, tie the POR/BOR pin to VCC. To use them, tie the POR/BOR pin to GND.
The XIN pin is the input clock pin, and the XOUT pin is the output clock pin. They are used to connect an external crystal oscillator or ceramic resonator to the device.