A good PCB layout is crucial for the UC2637DWG4. TI recommends a 4-layer board with a solid ground plane, and the use of vias to connect the top and bottom layers. Keep the input and output traces short and separate, and use a common mode choke to reduce EMI.
Choose input capacitors with low ESR and high ripple current ratings. For output capacitors, select ones with low ESR, high capacitance, and a voltage rating that meets or exceeds the output voltage. TI recommends using X5R or X7R ceramic capacitors.
The UC2637DWG4 is rated for operation up to 85°C ambient temperature. However, for reliable operation, it's recommended to keep the ambient temperature below 70°C to ensure the device stays within its thermal specifications.
Use a heat sink with a thermal resistance of 10°C/W or less, and ensure good airflow around the device. Apply a thin layer of thermal interface material (TIM) between the device and heat sink. Keep the heat sink away from other components to prevent thermal coupling.
Use a common mode choke and a differential mode filter to reduce EMI. Shield the device and surrounding components with a metal enclosure or shielded box. Ensure good grounding and use EMI-absorbing materials to reduce radiation.