A 4-layer PCB with a solid ground plane and thermal vias is recommended. Ensure that the thermal pad is connected to a large copper area to dissipate heat efficiently.
Use a combination of capacitors and inductors to filter the output. A 10uF ceramic capacitor and a 1uH inductor are recommended. Additionally, consider using a pi-filter configuration for further noise reduction.
The maximum input voltage is 5.5V. Exceeding this voltage may damage the device. Ensure that the input voltage is within the recommended range of 3.5V to 5.5V.
Implement a thermal management strategy, such as using a heat sink or a thermal interface material, to keep the junction temperature below 125°C. Monitor the device's temperature using the thermal monitoring pin (TMP) and adjust the system design accordingly.
A 10uF to 22uF ceramic capacitor is recommended for input decoupling. This value helps to filter out noise and ensures stable operation.