The maximum operating temperature range for the VCP15US12 is -40°C to +85°C, with a derating of 2.5% per °C above 60°C.
The VCP15US12 meets various safety certifications, including UL60950, EN60950, and IEC60950. Ensure you follow the recommended layout and installation guidelines to maintain these certifications.
The recommended input fuse value for the VCP15US12 is 2A slow-blow. However, this may vary depending on the specific application and input voltage.
Yes, the VCP15US12 is designed to withstand high-vibration environments. It meets the IEC 60068-2-6 vibration test standard, which simulates vibrations up to 10G.
The power dissipation of the VCP15US12 can be calculated using the formula: Pd = (Vin - Vout) x Iout. Where Vin is the input voltage, Vout is the output voltage, and Iout is the output current.