2a92
Abstract: 3B9335 3C9343 AT29C010 32PDIP
Contextual Info: PAGE 1 OF 8 ATMEL CORPORATION Tel: 408 441-0311 Fax:(408)436-4200 AT-29C010 PEROM RELIABILITY DATA - 125°C DYNAMIC OPERATING LIFE TEST - 200°C RETENTION BAKE - CYCLE TEST - 125°C DYNAMIC OPERATING LIFE TEST (PLASTIC) - 150°C RETENTION BAKE (PLASTIC) - 85°C/85% RELATIVE HUMIDITY OPERATING LIFE TEST
|
Original
|
AT-29C010
AT-29C010
3A0946-2
3A1195
3C0337
3D0897
3C0714
4A0088
4A1536
4A1990
2a92
3B9335
3C9343
AT29C010
32PDIP
|
PDF
|
29C256
Abstract: 29C257 report on PLCC tsop 6 MIL-M-38535 3A0081
Contextual Info: PAGE 1 OF 8 ATMEL CORPORATION Tel: 408 441-0311 Fax: (408) 436-4200 AT-29C256 PEROM RELIABILITY DATA - 125°C DYNAMIC OPERATING LIFE TEST - CYCLE TEST - 200°C RETENTION BAKE - 125°C DYNAMIC LIFE TEST (PLASTIC) - 125°C RETENTION BAKE (PLASTIC) - 15 PSIG PRESSURE POT
|
Original
|
AT-29C256
MIL-M-38535
AT-29C257
AT-29C256
2D9303
3A9313
3A9318
3B9324
29C256
29C257
report on PLCC
tsop 6
3A0081
|
PDF
|
89C2051
Abstract: atmel 89C2051 at89C2051 sample AT89C2051 MIL-M-38535 8A9813 8A98 4D9510 4D9509
Contextual Info: PAGE 1 OF 7 ATMEL CORPORATION Tel: 408 441-0311 Fax: (408) 436-4200 AT-89C2051 FLASH MICRO CONTROLLER RELIABILITY DATA* - 125°C OPERATING LIFE TEST - 125°C OPERATING LIFE TEST (PLASTIC) - 150°C DATA RETENTION BAKE (PLASTIC) - 15 PSIG PRESSURE POT - 131°C/85% RELATIVE HUMIDITY HAST TEST
|
Original
|
AT-89C2051
MIL-M-38535
AT-89C51
AT-89C52
AT-89C2051
8H0869-4
8H9840
8H2123
8H9849
89C2051
atmel 89C2051
at89C2051 sample
AT89C2051
8A9813
8A98
4D9510
4D9509
|
PDF
|
29C256
Abstract: 29C257 PLCC 64
Contextual Info: PAGE 1 OF 8 ATMEL CORPORATION Tel: 408 441-0311 Fax: (408) 436-4200 AT-29C256 PEROM RELIABILITY DATA - 125°C DYNAMIC OPERATING LIFE TEST - CYCLE TEST - 200°C RETENTION BAKE - 125°C DYNAMIC LIFE TEST (PLASTIC) - 125°C RETENTION BAKE (PLASTIC) - 15 PSIG PRESSURE POT
|
Original
|
AT-29C256
MILM-38535
AT-29C257
AT-29C256
2D9303
3A9313
3A9318
3B9324
29C256
29C257
PLCC 64
|
PDF
|
89C2051
Abstract: atmel 89c52 89c2051 data sheet atmel 89c2051 datasheet 89c2051 controller atmel 89c2051 at89C2051 sample atmel 89C51 3J0412 AT89C2051
Contextual Info: PAGE 1 OF 7 ATMEL CORPORATION Tel: 408 441-0311 Fax: (408) 436-4200 AT-89C2051 FLASH MICRO CONTROLLER RELIABILITY DATA* - 125°C OPERATING LIFE TEST - 125°C OPERATING LIFE TEST (PLASTIC) - 150°C DATA RETENTION BAKE (PLASTIC) - 15 PSIG PRESSURE POT - 131°C/85% RELATIVE HUMIDITY HAST TEST
|
Original
|
AT-89C2051
MIL-M-38535
AT-89C51
AT-89C52
AT-89C2051
8H2123
8H9849
9H2120
9H9923
89C2051
atmel 89c52
89c2051 data sheet
atmel 89c2051 datasheet
89c2051 controller
atmel 89c2051
at89C2051 sample
atmel 89C51
3J0412
AT89C2051
|
PDF
|