COMMSCOPE Search Results
COMMSCOPE Price and Stock
COMMSCOPE Datasheets Context Search
Catalog Datasheet | Type | Document Tags | |
---|---|---|---|
belden ra7000
Abstract: RA7000
|
OCR Scan |
RG-I74, YR23023 RG-59 RA7000 375-32UNEF-2A belden ra7000 | |
grs-500-ch-du-03-t
Abstract: GRS-320-CH-QR-T GRS-565-CH-TX GRS-412-CH-DU-01-T GRS-440-CH-MC2-T
|
Original |
GRS-412-CH-DU-01-T GRS-500-CH-DU-03-T GRS-625-CH-DU-02-T GRS-750-CH-DU-01-T GRS-875-CH-DU-02-T GRS-1000-CH-DU-01-T GRS-320-CH-QR-T GRS-750-CH-FD-04-T GRS-750-CH-CX-T GRS-875-CH-CX-T GRS-320-CH-QR-T GRS-565-CH-TX GRS-440-CH-MC2-T | |
GRS-500-TR-CXContextual Info: GRS Cable Terminators Hex A Hex B Hex C Center Conductor Cutting Guide CommScope P-3 Times Fiber T-10 Cable Series Part Number Center Conductor Outer Conductor Body Hex A Main Nut Hex (B) Back Nut Hex (C) .412 GRS-412-TR-DU-01 .092 .412 15/16 1 15/16 .500 |
Original |
GRS-412-TR-DU-01 GRS-500-TR-DU-03 GRS-625-TR-DU-02 GRS-750-TR-DU-01 GRS-875-TR-DU-02 GRS-1000-TR-DU-01 GRS-320-TR-QR GRS-540-TR-QRP* GRS-715-TR-QRP* GRS-860-TR-QRP* GRS-500-TR-CX | |
GTC-540-QR-GHZ-N
Abstract: 1/GTC-500-MC2-GHZ-N
|
Original |
GTC-412-GHZ-N GTC-500-GHZ-N GTC-750-GHZ-N GTC-875-GHZ-N GTC-1000-GHZ-N GTC-500-QR-GHZ-N GTC-540-QR-GHZ-N GTC-715-QR-GHZ-N GTC-860-QR-GHZ-N GTC-1125-QR-GHZ-N 1/GTC-500-MC2-GHZ-N | |
Contextual Info: A Pi n and S p l i c e P o w e r Connectors c Pin Connector | : CABLE TYPE PART NUMBER STRIPPING/ JACKET CORING TOOL STRIPPER CommScope 50 ohm GRS-625/50-CH-122-T G-SCT-625/50 G-JCS-625 Times Fiber 50 ohm GRS-625/50-CH-122-T G-SCT-625/50 G-JCS-625 CommScope Power Feeder |
OCR Scan |
GRS-625/50-CH-122-T G-SCT-625/50 G-JCS-625 GRS-625/PF-CH-122-T G-SCT-625/PF | |
Contextual Info: True 75 Ohm BNC Straight Cabled Plug 3 Piece Solder or Crimp Captivated Contact PART NUMBER CABLE TYPE CPMC-68-33 Belden 735A Commscope 735, Helex/Hitemp 735 BT3002, TZC75024 CONTACT I.D. BODY I.D. FERRULE I.D. .021 0.53 .082 (2.08) .160 (4.06) INCHES (MILLIMETERS) |
Original |
CPMC-68-33 BT3002, TZC75024 | |
LV-775
Abstract: KTH-2138 CP-5407 1426a KTH-2178 734D KTH-2007 kth-2002 8241F Canare
|
OCR Scan |
2041K EPD0810 KTH-2002 1164B 1406B 1407B 1417B, 1818B 8241F 8281B, LV-775 KTH-2138 CP-5407 1426a KTH-2178 734D KTH-2007 kth-2002 Canare | |
Contextual Info: SD REVISIONS CHANGES ER 37747 DCT 12/18/98 K3 O 05 cn CN 37837 C TML 05/21/99 I O 1.22 REF. O I CO CN 37933 D TML 11/09/99 CN 37965 E DCT 02/29/00 CN 38011 D HVN 05/23/00 CN 38046 E DCT 7/10/00 .18 D. REF. CN 38144 C BDH 12/12/00 NOTES: 1. FOR USE WITH COMMSCOPE 77538 & BELDEN 1855A & 1865A CABLES. |
OCR Scan |
KTH-2025. 1-6690-7MA9, MIL-STD-348, ASTM-D-4894 ZZ-R-765 ASTM-B-196 ASTM-B16 | |
6262-T6511
Abstract: EFI625PF
|
Original |
EFI625PF 6262-T6511 EFI625PF | |
Commscope RG 59
Abstract: Commscope 7538 VPM2000 Commscope CPMC-68-20 TZC75024 Belden 9248 CABLE BELDEN coleman rg VSD2001
|
Original |
CPMC-68-2 RG-59, VJ59U CPMC-68-3 VP618PVC CPMC-68-5 CPMC-68-10 CPMC-68-18 CPMC-68-20 RG-179aterial Commscope RG 59 Commscope 7538 VPM2000 Commscope CPMC-68-20 TZC75024 Belden 9248 CABLE BELDEN coleman rg VSD2001 | |
MC 3041Contextual Info: STAMP: KINGS 1205-78-101 YRWK DATE CODE CENTER CONDUCTOR 1205-78—101SD NOTES: 1. FOR USE WITH COMMSCOPE CR 50 396 PE CABLE. 2. FOR CABLING INSTRUCTIONS SEE 3-692. 3. INTERFACE PER MIL-STD-348, FIG. 304-1. 4. CENTER CONTACT TO BE SUPPLIED UNASSEMBLED. 7. ELECTRICAL CHARACTERISTICS: |
OCR Scan |
MIL-STD-348, 1205-78--101SD MC 3041 | |
CP-465Contextual Info: TRUE 75 Ohm BNC Connectors Splices, Bulkhead Jacks and Receptacle Figure 4 Figure 6 Figure 5 Mounting Holes Splices KINGS Part Number True 75 Ohm Belden CommScope West Penn/CDT 4 3050-10-9 734D1 735A1 734C1 73501 CBL1235 CBL1288 734 to 735 Cabling Dimensions |
Original |
734D1 735A1 734C1 CBL1235 CBL1288 KTH-2185 KTH-2186 KTH-2185 CP-465 | |
Contextual Info: REVISIONS C-n I ER 38394 cn cn HVN 09/11/01 I CD I NOTES: 1. FOR USE WITH COMMSCOPE CR 50 540 PE CABLE. 2. FOR CABLING INSTRUCTIONS SEE 3-692. 3. INTERFACE PER IEC STANDARD 169-4 TYPE 7-16 MM, AS APPLICABLE. 4. MATERIALS: INSULATOR: TEFLON. GASKET: SILICONE RUBBER. |
OCR Scan |
3155--6--101SD E--19941 | |
101SDContextual Info: YRWK DATE CODE PROPOSED TRIM DIM’S REVISIONS C-nI ER en en 38394 HVN 09/11/01 I en I NOTES: 1. FOR USE WITH COMMSCOPE CR 50 396 PE CABLE. 2. FOR CABLING INSTRUCTIONS SEE 3-692. 3. INTERFACE PER IEC STANDARD 169-4 TYPE 7 -1 6 MM, AS APPLICABLE. 4. MATERIALS: |
OCR Scan |
101SD 101SD | |
|
|||
Contextual Info: True 75 Ohm BNC Straight Cabled Plug 3 Piece Solder or Crimp Captivated Contact PART NUMBER CABLE TYPE CPMC-68-3 Belden 8281, 9231, 9141, 735A Commscope 7501 VP618PVC CONTACT I.D. BODY I.D. FERRULE I.D. .036 0.91 .203 (5.16) .330 (8.38) INCHES (MILLIMETERS) |
Original |
CPMC-68-3 VP618PVC | |
Commscope 750 P1
Abstract: Commscope 500 P1 G2-500-AFM-MC2 G-KS-KS-M
|
Original |
G2-500-AFM-P3 G2-625-AFM-P3 G2-750-AFM-P3 G2-875-AFM-P3 G2-540-AFM-QR* G2-715-AFM-QR* G2-860-AFM-QR* TX-10 G2-565-AFM-TX G2-700-AFM-TX Commscope 750 P1 Commscope 500 P1 G2-500-AFM-MC2 G-KS-KS-M | |
Commscope 500 P1Contextual Info: G2 Extension Connectors 1 [25.4 mm] CENTER CONDUCTOR CUTTING GUIDE 3.00 [76.2 mm] 2.31 [58.8 mm] .31 [8.0 mm] .067 [1.7 mm] Dia. Pin 5/8-24 THD 3/4 [19.1 mm] HEX Hex B Hex A CommScope P-3 Times Fiber T-10 Cable Series Part Number Center Conductor Outer Conductor Body Hex A Back Nut Hex (B) |
Original |
G2-500-EXT-3-P3 G2-625-EXT-3-P3 G2-750-EXT-3-P3 G2-875-EXT-3-P3 G2-540-EXT-3-QR* G2-715-EXT-3-QR* G2-860-EXT-3-QR* TX-10 G2-565-EXT-3-TX G2-700-EXT-3-TX Commscope 500 P1 | |
Contextual Info: G H z S e r i e s Push On Lab Connector Note: Lab Connectors on this page are designed to be used up to 1 GHz. ‘ CommScope P -lll" ! CONNECTOR PART NUMBER REFURBISHMENT KIT PART NUMBER Tim es Fiber T -1 J |J GTC-412-GHZ-N NS-6595-7 GTC-500-GHZ-N NS-6595-9 |
OCR Scan |
GTC-412-GHZ-N NS-6595-7 GTC-500-GHZ-N NS-6595-9 GTC-625-GHZ-N NS-6595-11 GTC-750-GHZ-N NS-6595-13 GTC-875-GHZ-N NS-6595-3 | |
Contextual Info: Microwave Backhaul Solutions Does your Microwave Backhaul Network Have a Survival Strategy? ExtremeLine Antennas: Extreme Performance for Extreme Conditions ExtremeLine Antennas ® Extreme Performance for Extreme Conditions Demanding environments call for rugged CommScope engineering to ensure |
Original |
EIA195, BR-105563 | |
Commscope 7538Contextual Info: DASH NO. M CODE MADE FROM YRWK DATE CODE NOTES: 1. FOR USE WITH BELDEN 1855A, 1865A & COMMSCOPE 7538 CABLES. 2. FOR CABLING INSTRUCTIONS SEE 3-661-1. 3. FOR CRIMPING USE DIE KTH-2185. 4. SLEEVE AND CENTER CONTACT TO BE SUPPLIED UNASSEMBLED. 5. INTERFACE PER KINGS STANDARD E S - 17, FIG. 5. |
OCR Scan |
KTH-2185. 2022-32-9S E--20033 Commscope 7538 | |
mohawk M80248
Abstract: M80248 7812 metal cap KTH-8000 7812 all electrical for 7812 7814
|
OCR Scan |
1006900C, M80248 KTH-8000 KTH-8001. ASTM-D-4894 ZZ-R-765 ASTM-B-135 ASTM-B-196 mohawk M80248 M80248 7812 metal cap 7812 all electrical for 7812 7814 | |
teflon gasketContextual Info: REVISIONS ER 38394 HVN 09/11/01 STAMP: KINGS 1205-78-101 YRWK DATE CODE NOTES: 1. FOR USE WITH COMMSCOPE CR 50 396 PE CABLE. 2. FOR CABLING INSTRUCTIONS SEE 3-692. 3. INTERFACE PER MIL-STD-348, FIG. 304-1. 4. CENTER CONTACT TO BE SUPPLIED UNASSEMBLED. 5. MATERIALS: |
OCR Scan |
MIL-STD-348, 1205--78--101SD E-19909 teflon gasket | |
Commscope 7538
Abstract: commscope 7538 b cable 1855A Commscope CRIMPING BNC 75 OHM
|
Original |
CPMC-68-34 MIL-C-39012) MIL-STD-202, Commscope 7538 commscope 7538 b cable 1855A Commscope CRIMPING BNC 75 OHM | |
Contextual Info: A C a b l e Groups .412 Cable A B n - ' c F USE COMMSCOPE P-tll / TIMES T-10 .500 PRODUCTS CABLE TYPE SOLID COPPER COPPER CLAD ALUMINUM CENTER CONDUCTOR CENTER CONDUCTOR C a n a d a W ire P o lye th yle n e A L -4 1 2 7 5 C e rro A lu m in u m S h e a th 1 4 1 2-S C |
OCR Scan |